; ISINAC ACOUSTIC WORLD S.L.U. - absorption library for CATT-Acoustic
; Generated 2026_08_21 from ISINAC's master test catalogue.
; VAT ESB27853381 - www.isinac.com - info@isinac.com
;
; Values are absorption in PERCENT, octave bands 125 Hz to 4 kHz.
; 8 kHz and 16 kHz are NOT given: they were not tested. CATT extrapolates.
; Where the reverberation-room measurement exceeded 100 %, the value is
; capped at 99 as the CATT manual requires for geometrical acoustics.
; The real measured third-octave curves (up to 148 %) are in the test reports.
;
; SCATTERING IS NOT GIVEN. ISINAC has no ISO 17497-1 test, and writing 0
; would mean purely specular reflection - false for our profiled products.
; For those, CATT's own estimate() can be used with the real depth. Syntax:
;     ABS <name> = < ...six octaves... >  L < estimate(<depth in metres>) >
; NOTE: the line above is SYNTAX ONLY - it carries no ISINAC data. Take the
; six values from the material you are using, below, and the depth from its
; description. Never copy example numbers into a model.
; ------------------------------------------------------------------







ABS ISINAC_CURTAIN_ILUCS_1_capa_c300 = <15 40 40 40 50 60>
C: ISINAC textile
D: 300 mm air cavity, mounting G-300 (ISO 354 Annex B), alpha_w 0.45 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: 115541-3, Fundacion Tecnalia R&I

ABS ISINAC_CURTAIN_ILUCS_2_capas_c200 = <20 55 85 80 85 99>
C: ISINAC textile
D: 200 mm air cavity, mounting G-200 (ISO 354 Annex B), alpha_w 0.80 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: 110259-6, Fundacion Tecnalia R&I

ABS ISINAC_CURTAIN_ILUCS_4_capas_c200 = <25 90 99 99 99 99>
C: ISINAC textile
D: 200 mm air cavity
R: B2019-LACUS-IN-54 V, Fundacion Tecnalia R&I

ABS ISINAC_CURTAIN_IZZER_1_capa_c300 = <20 65 75 80 85 90>
C: ISINAC textile
D: 300 mm air cavity, mounting G-300 (ISO 354 Annex B)
R: 115541-2, Fundacion Tecnalia R&I

ABS ISINAC_CURTAIN_IZZER_4_capas_c200 = <30 90 99 99 99 99>
C: ISINAC textile
D: 200 mm air cavity, mounting G-200 (ISO 354 Annex B)
R: B2023-LACUS-IN-195-4, Fundacion Tecnalia R&I

ABS ISINAC_CURTAIN_PX500_1_capa_c300 = <25 65 75 75 90 99>
C: ISINAC textile
D: 300 mm air cavity, mounting G-300 (ISO 354 Annex B), alpha_w 0.80 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: 115541-1, Fundacion Tecnalia R&I

ABS ISINAC_ELYPSIUM_aleatorio_ILUCS_305mm = <40 80 90 80 80 70>
C: ISINAC free-standing
D: free-standing object, alpha_obj referred to S=2.44 m2, 305 mm thick
R: B2019-LACUS-IN-83 II, Fundacion Tecnalia R&I

ABS ISINAC_ELYPSIUM_esquina_ILUCS_305mm = <50 70 70 50 50 40>
C: ISINAC free-standing
D: free-standing object, alpha_obj referred to S=2.44 m2, 305 mm thick
R: B2019-LACUS-IN-83 III, Fundacion Tecnalia R&I

ABS ISINAC_FT_PANEL_40mm = <10 40 75 85 95 95>
C: ISINAC absorber
D: 40 mm thick, alpha_w 0.70 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: B2017-LACUS-IN-30 I, Laboratorio de Control de Calidad de la Edificacion del Gobierno Vasco (Vitoria-Gasteiz) - Area de Acustica gestionada por TECNALIA

ABS ISINAC_FT_PANEL_COOLTEX_40mm = <10 40 75 90 95 95>
C: ISINAC absorber
D: 40 mm thick, alpha_w 0.70 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: B2017-LACUS-IN-30 II, Laboratorio de Control de Calidad de la Edificacion del Gobierno Vasco (Vitoria-Gasteiz) - Area de Acustica gestionada por TECNALIA

ABS ISINAC_FT_PANEL_MUSLI_40mm = <20 40 65 75 50 35>
C: ISINAC absorber
D: 40 mm thick, alpha_w 0.50 (M) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: B2017-LACUS-IN-30 III, Laboratorio de Control de Calidad de la Edificacion del Gobierno Vasco (Vitoria-Gasteiz) - Area de Acustica gestionada por TECNALIA

ABS ISINAC_HYBRID_ILUCS = <50 95 99 95 95 90>
C: ISINAC absorber
D: ISINAC acoustic absorber
R: B2019-LACUS-IN-83 I, Fundacion Tecnalia R&I

ABS ISINAC_ISTORE_IZZER_c100 = <5 20 50 75 60 65>
C: ISINAC textile
D: 100 mm air cavity, mounting G-100 (ISO 354 Annex B), alpha_w 0.50 (MH) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: B2023-LACUS-IN-195-3, Fundacion Tecnalia R&I

ABS ISINAC_LINEAR_IZZER_100mm = <15 30 60 80 80 80>
C: ISINAC absorber
D: 100 mm thick, alpha_w 0.60 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 150 mm entre ellos, cara adhesiva contra el suelo y el tejido IZZER de todas las lamas al mismo lado, cubriendo 11,44 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: B2023-LACUS-IN-195-1, Fundacion Tecnalia R&I

ABS ISINAC_LINEAR_100mm = <15 35 60 85 95 95>
C: ISINAC absorber
D: 100 mm thick, alpha_w 0.60 (MH) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 150 mm entre ellos, cara adhesiva contra el suelo, cubriendo 11,44 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: B2023-LACUS-IN-195-2, Fundacion Tecnalia R&I

ABS ISINAC_NENUFAR_ILUCS_PX_7mm_c400 = <25 65 70 85 99 99>
C: ISINAC absorber
D: 7 mm thick, 400 mm air cavity, alpha_w 0.80 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: 110259-8, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_20mm = <5 15 40 70 90 99>
C: ISINAC absorber
D: 20 mm thick, alpha_w 0.40 (MH) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 30 mm entre ellos, cara oculta orientada hacia el suelo, cubriendo 12,08 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: 110259-2, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_IZZER_pegado_20mm = <10 35 65 90 75 55>
C: ISINAC absorber
D: 20 mm thick, alpha_w 0.65 (M) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 20 mm entre ellos, cara oculta orientada hacia el suelo, cubriendo 11,92 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: B2021-LACUS-IN-146-1, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_40mm = <15 45 80 99 99 99>
C: ISINAC absorber
D: 40 mm thick, alpha_w 0.75 (MH) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 30 mm entre ellos, cara con adhesivo contra el suelo, cubriendo 12,08 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: B2018-LACUS-IN-27 III, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_40mm_c400 = <15 35 80 99 99 99>
C: ISINAC absorber
D: 40 mm thick, 400 mm air cavity, alpha_w 0.65 (MH) per ISO 11654 clause 4.3 - use together with the full absorption curve  NO es un bafle suspendido. El informe dice: 'The panels are placed at 400 mm above the floor of the test room, with a distance of 30 mm between them, with the hidden face oriented towards the floor'. Absorbe por UNA cara sobre plenum. Modelarlo como bafle a dos caras duplica el area absorbente.
R: B2019-LACUS-IN-54 I, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_ILUCS_40mm = <15 55 99 99 99 99>
C: ISINAC absorber
D: 40 mm thick, alpha_w 0.85 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 30 mm entre ellos, cara de tejido expuesta al sonido, cubriendo 12,08 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: B2018-LACUS-IN-27 II, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_ILUCS_40mm_c400 = <20 50 95 99 99 99>
C: ISINAC absorber
D: 40 mm thick, 400 mm air cavity, alpha_w 0.80 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve  NO es un bafle suspendido. El informe dice: 'The panels are placed at 400 mm above the floor of the test room, with a distance of 30 mm between them, with the hidden face oriented towards the floor'. Absorbe por UNA cara sobre plenum. Modelarlo como bafle a dos caras duplica el area absorbente.
R: B2019-LACUS-IN-54 II, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_IZZER_funda_40mm = <15 60 99 99 99 99>
C: ISINAC absorber
D: 40 mm thick, Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 30 mm entre ellos, cara oculta orientada hacia el suelo, cubriendo 12,08 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: B2021-LACUS-IN-146-3, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_IZZER_pegado_40mm_c400 = <50 55 55 55 50 45>
C: ISINAC absorber
D: 40 mm thick, 400 mm air cavity
R: B2021-LACUS-IN-146-4, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_ILEATHER_40mm = <15 50 90 99 99 95>
C: ISINAC absorber
D: 40 mm thick, alpha_w 0.80 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 40 mm entre ellos, cara oculta orientada hacia el suelo, cubriendo 12,01 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: B2022-LACUS-IN-172-1, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_IZZER_pegado_40mm = <30 55 75 85 50 40>
C: ISINAC absorber
D: 40 mm thick, alpha_w 0.55 (M) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 30 mm entre ellos, cara oculta orientada hacia el suelo, cubriendo 12,08 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: B2021-LACUS-IN-146-2, Fundacion Tecnalia R&I







ABS ISINAC_PLAN_60mm = <30 80 99 99 99 99>
C: ISINAC absorber
D: 60 mm thick, Segun el informe: los paneles se colocan sobre el suelo de la camara reverberante con una separacion de 30 mm entre ellos, cara oculta orientada hacia el suelo, cubriendo 12,08 m2. Criterio de ISINAC, no del laboratorio: con esa separacion queda canto de panel expuesto al sonido, asi que un revestimiento CONTINUO sin junta absorbe MENOS que lo que dice esta ficha.
R: 110259-1, Fundacion Tecnalia R&I

ABS ISINAC_PLAN_BS_52mm_c400 = <30 75 99 99 99 99>
C: ISINAC absorber
D: 52 mm thick, 400 mm air cavity, CORREGIDO 2026_08_10. El nombre del fichero dice ADH y el informe dice otra cosa: 'Configuration of panels ISINAC C.610.52 BS with a separation of 400 mm from a surface'. El 'adhered' de la composicion se refiere a las DOS CAPAS DE ESPUMA pegadas ENTRE SI (14 y 38 mm), no al montaje en pared. Publicarlo como panel adherido da el DOBLE de absorcion real en 125-250 Hz.  Paneles a 400 mm del suelo, con 30 mm de separacion entre ellos.
R: 110259-3, Fundacion Tecnalia R&I

ABS ISINAC_PX500_FV450_PX500 = <5 15 40 75 95 99>
C: ISINAC absorber
D: alpha_w 0.40 (MH) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: B2018-LACUS-IN-19, Fundacion Tecnalia R&I

ABS ISINAC_TENS_TEX_ILUCS_15mm = <5 20 50 80 99 99>
C: ISINAC absorber
D: 15 mm thick, alpha_w 0.50 (MH) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: modulos con perfil de PVC fijado mecanicamente al perimetro de una base de contrachapado de 10 mm, con la espuma adherida a la base. Se colocan sobre el suelo de la camara CON JUNTA A TOPE (butt joint), el contrachapado contra el suelo, cubriendo 11,16 m2, DENTRO DE UN MARCO PERIMETRAL de tablero de particulas de 30 mm de grosor por 25 mm de alto, y con las juntas modulo-marco y marco-suelo SELLADAS CON CINTA ADHESIVA. No hay junta abierta entre modulos: los 30 mm son el grosor del marco.
R: B2023-LACUS-IN-195-7, Fundacion Tecnalia R&I

ABS ISINAC_TENS_TEX_IZZER_15mm = <5 20 50 80 99 99>
C: ISINAC absorber
D: 15 mm thick, alpha_w 0.50 (MH) per ISO 11654 clause 4.3 - use together with the full absorption curve  Segun el informe: modulos con perfil de PVC fijado mecanicamente al perimetro de una base de contrachapado de 10 mm, con la espuma adherida a la base. Se colocan sobre el suelo de la camara CON JUNTA A TOPE (butt joint), el contrachapado contra el suelo, cubriendo 11,16 m2, DENTRO DE UN MARCO PERIMETRAL de tablero de particulas de 30 mm de grosor por 25 mm de alto, y con las juntas modulo-marco y marco-suelo SELLADAS CON CINTA ADHESIVA. No hay junta abierta entre modulos: los 30 mm son el grosor del marco.
R: B2023-LACUS-IN-195-5, Fundacion Tecnalia R&I

ABS ISINAC_TENS_TEX_IZZER_sin_espuma_15mm = <5 10 20 25 50 80>
C: ISINAC absorber
D: 15 mm thick, alpha_w 0.25 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve
R: B2023-LACUS-IN-195-6, Fundacion Tecnalia R&I



ABS ISINAC_WB_ILUCS_33mm_c400 = <35 80 95 99 99 99>
C: ISINAC wall panel
D: 33 mm thick, 400 mm air cavity, Ensayado con junta a tope (butt joint) entre paneles, separados 400 mm de la superficie.
R: 110259-5, Fundacion Tecnalia R&I

ABS ISINAC_WB_HP_ILUCS_140mm_c400 = <65 95 99 99 99 99>
C: ISINAC wall panel
D: 140 mm thick, 400 mm air cavity, Ensayado con junta a tope (butt joint) entre paneles, separados 400 mm de la superficie.
R: 110259-7, Fundacion Tecnalia R&I

ABS ISINAC_WB_IMECO_IZZER_33mm_c400 = <30 70 70 85 95 99>
C: ISINAC wall panel
D: 33 mm thick, 400 mm air cavity, alpha_w 0.80 (H) per ISO 11654 clause 4.3 - use together with the full absorption curve  Ensayado con junta a tope (butt joint) entre paneles, separados 400 mm de la superficie.
R: 110259-4, Fundacion Tecnalia R&I

ABS ISINAC_WH_40mm = <5 30 90 65 75 55>
C: ISINAC absorber
D: 40 mm thick, alpha_w 0.60 (M) per ISO 11654 clause 4.3 - use together with the full absorption curve  El informe 2011/1496-B de Istituto Giordano es una hoja de resultados y no describe la disposicion de la probeta. Consta una probeta unica de 3,502 x 3,007 m = 10,53 m2. La condicion de borde NO CONSTA en el informe, y por eso no se afirma ninguna.
R: Istituto Giordano 2011/1496-B, Istituto Giordano