Fire-retardant fabric: what Euroclass B-s1,d0, M1, B1 and IMO mean

November 13, 2026 · News
Dining room of a restaurant with ILUCS curtains separating the spaces

Quick answer: a fire-retardant fabric is one that has passed a reaction to fire test in a laboratory and has a classification. In Europe, that classification is the Euroclass from the EN 13501-1 standard (for example, B-s1,d0: class B, the lowest smoke level and no flaming droplets); France uses M classes (M1), Germany uses DIN 4102 (B1), the United States uses NFPA 701 and ships use the IMO FTP Code. Each system has its own test, and one classification does not replace another. Furthermore, the classification of the fabric is not that of the panel: ILUCS alone is B-s1,d0 and the mineral foam panel with ILUCS finish is C-s2,d0.

What is a fire-retardant fabric?

"Fire-retardant" is used to describe a fabric that performs well when exposed to a flame. However, the word alone is not enough: what matters is the test report. Before approving a fabric, check four details on that document: which standard was applied, which laboratory conducted it, which sample was tested, and what result was achieved. With this information, you can compare one fabric to another and determine whether it meets your project requirements.

There are several standards because each country, and each application, has its own. This table summarizes the most commonly requested ones for fabrics and curtains:

StandardWhere it is requiredWhat is testedHow it is expressed
EN 13501-1European Union, construction products (flooring has its own "fl" classifications)Single Burning Item test (EN 13823) and small ignitability test (EN ISO 11925-2)Classes A1 to F, plus smoke (s1 to s3) and droplets (d0 to d2)
NF P 92-507France, interior acoustic treatmentElectric burner on flexible materials under 5 mm (NF P 92-503), flame propagation speed (NF P 92-504) and droplets (NF P 92-505)Classes M0 to M4
DIN 4102-1GermanyIts own testClasses A1, A2, B1, B2, and B3
NFPA 701United States: curtains, drapes, awnings, and filmsFlame spread, using two methods depending on the weight and type of materialPass or fail
EN 13773European Union, curtainsFire behavior classification of curtains5 classes
BS 5867-2United Kingdom, curtain and blind fabricsFlammabilityTypes A, B, and C
IMO FTP Code 2010 (Resolution MSC.307(88)), part 7ShipsTextiles and films placed verticallyPass or fail

What does Euroclass B-s1,d0 mean?

The Euroclass rating consists of three parts. The letter indicates the material's contribution to fire, ranging from A1 to F. The "s" indicates the amount of smoke produced: s1, s2, or s3. The "d" indicates whether flaming droplets or particles are formed: d0, d1, or d2. Thus, B-s1,d0 reads: Class B, the lowest smoke level, and no flaming droplets.

The laboratory does not assign the class by eye: it derives it from test measurements. These are the ones shown in the tables below:

  • FIGRA: how fast the heat released by the sample grows. It is calculated using two thresholds, 0.2 MJ and 0.4 MJ.
  • THR 600 s: the total heat released by the sample in the first 600 seconds.
  • Lateral flame spread: whether the flame travels across the sample to reach the edge.
  • SMOGRA: how fast the sample produces smoke.
  • TSP 600 s: the total smoke produced by the sample in the first 600 seconds.

With these measurements, each class requires the following. It is the table from the EN 13501-1 standard, from A2 to F, for non-floor construction products:

ClassRequirements (average values)
A2FIGRA 0.2 MJ ≤ 120 W/s · flame does not reach the edge · THR 600 s ≤ 7.5 MJ · and additionally EN ISO 1182 or EN ISO 1716
BFIGRA 0.2 MJ ≤ 120 W/s · the flame does not reach the edge · THR 600 s ≤ 7.5 MJ · and also EN ISO 11925-2
CFIGRA 0.4 MJ ≤ 250 W/s · flame does not reach edge · THR 600 s ≤ 15 MJ · plus EN ISO 11925-2
DFIGRA 0.4 MJ ≤ 750 W/s · and also EN ISO 11925-2
EEN ISO 11925-2, with 15 s flame: the tip of the flame does not rise more than 150 mm in 20 s
FFails to reach class E

And these are the smoke and droplet classifications added to the main letter grade:

Additional classRequirements (average values)
s1SMOGRA ≤ 30 m²/s² and TSP 600 s ≤ 50 m²
s2SMOGRA ≤ 180 m²/s² and TSP 600 s ≤ 200 m²
s3Does not reach s1 or s2
d0No flaming droplets or particles within 600 seconds
d1No drops or particles that continue burning for more than 10 seconds, within 600 seconds
d2Does not reach d0 or d1

Why does the fabric test differ from the complete panel test?

Because something else is being tested. The fabric is tested alone, glued onto a standardized calcium silicate board; the panel also features a mineral foam core, and that core burns in a different way. Our own reports show this with numbers:

MeasurementILUCS, the fabric alone (BTTG 27/05749D/11/21)40 mm mineral foam (TECNALIA 080046-001-2-a)
FIGRA 0.2 MJ22.3 W/s141.14 W/s
FIGRA 0.4 MJ18.8 W/s39.0 W/s
THR 600 s1.4 MJ1.29 MJ
SMOGRA0 m²/s²65.50 m²/s²
TSP 600 s33.2 m²37.46 m²
Flaming dropletsNoNo
EN 13501-1 classB-s1,d0C-s2,d0

Example: mineral foam has a FIGRA 0.2 MJ of 141.14 W/s. It exceeds 120, so it cannot be B. Its FIGRA 0.4 MJ (39.0 W/s) and its THR (1.29 MJ) comfortably fit into C. And its SMOGRA, 65.50 m²/s², exceeds 30: that is why it is s2 and not s1. ILUCS, on the other hand, stays at 22.3 W/s and its SMOGRA is 0: B-s1,d0.

For this reason, the 40 mm self-adhesive mineral foam panel with ILUCS finish is declared C-s2,d0, which is the class of the foam. If someone provides you with the fire class of a fabric as if it were that of the panel, ask them for the panel's test report.

What is class M1?

It is the French classification for interior fitting materials, defined in standard NF P 92-507, which ranges from M0 to M4. For fabrics, it relies on other tests: the electric burner test for flexible materials under 5 mm (NF P 92-503), the flame propagation speed test (NF P 92-504), and the dripping test for melting materials (NF P 92-505).

ILUCS complies with class M1 according to approval 260340.1 from Indorama Ventures, the manufacturer of Trevira CS fiber, which covers the testing of ILUCS according to NF P 92-504.

What is class B1?

It is one of the classes within the German standard DIN 4102-1, which classifies materials into A1, A2, B1, B2, and B3. ILUCS meets the requirements for class B1, as stated in approvals 260340.1 and 250347.1 by Indorama Ventures.

And what about NFPA 701 in the United States?

It is the North American standard for flame propagation in textiles and films: curtains, drapes, awnings. It has two methods, selected according to material weight and type. ILUCS passes NFPA 701:2010 Method 1, according to Indorama Ventures approval 250347.1. That same approval also includes Class 1 under EN 13773 for curtains and Type C under British BS 5867-2.

What does the IMO FTP Code require from marine fabrics?

On ships, the International Maritime Organization (IMO) governs. Its 2010 FTP Code (Resolution MSC.307(88)) has a Part 7 for vertically oriented textiles and films, such as curtains. The fabric is not suitable if it exhibits any of the characteristics in the left-hand column. ILUCS was tested at AITEX (report 2024AU1433) and the report concludes that it complies:

The fabric is NOT suitable if…ILUCS (AITEX 2024AU1433)
The flame persists for more than 5 seconds on any specimenNo flame persistence in any test
Burns to any of the edgesComplies
The cotton placed underneath catches fireThe cotton did not ignite
Average charred length exceeds 150 mm83.2 mm (warp) and 82.2 mm (weft)
A surface flashover extends more than 100 mmNo surface flaming

Inherent or treated fire-retardant: what is the difference?

A fabric can behave well in reaction to fire in two ways. In inherently fire-retardant fabric, the property comes from the fiber itself. In treated fabric, a fire-retardant product is applied to the fabric afterward; for this reason, laboratories note in the report whether the sample has been treated, in how many layers, and in what amount.

ILUCS is inherently fire-retardant: it is 100 % Trevira CS polyester, and the AITEX IMO report states «flame retardant treatment: no». Indorama Ventures, the fiber manufacturer, verifies that ILUCS is 100 % Trevira CS and grants the use of its trademark (approvals 260340.1 and 250347.1).

IZZER is also fire-retardant by nature: it is virgin merino wool, without fire-retardant treatment.

ILUCSIZZER
Composition100% Trevira CS polyestervirgin merino wool
Why it is fire-retardantInherent to the fiber: without flame-retardant treatment (AITEX 2024AU1433)Due to the fibre: merino wool without fire-retardant treatment
Warranty (ISINAC general terms and conditions)10 years10 years
EN 13501-1 classB-s1,d0C-s1,d0

Whether original or treated, request the report and verify that the tested sample is that exact fabric: laboratories warn in their reports that the result is valid only for the tested sample.

What classification do our fabrics have?

FabricStandardResultReport or certificate
ILUCSEN 13501-1B-s1,d0BTTG 27/05749D/11/21
ILUCSNF P 92-507M1Indorama Ventures 260340.1
ILUCSDIN 4102-1B1Indorama Ventures 260340.1 and 250347.1
ILUCSNFPA 701:2010, method 1CompliesIndorama Ventures 250347.1 (300 g/m² grey ILUCS)
ILUCSEN 13773Class 1Indorama Ventures 250347.1 (300 g/m² grey ILUCS)
ILUCSBS 5867-2Type CIndorama Ventures 250347.1 (300 g/m² grey ILUCS)
ILUCSIMO FTP Code 2010, Part 7CompliesAITEX 2024AU1433
IZZER (merino virgin wool)EN 13501-1C-s1,d0BTTG 27/05749B/11/21
PX500EN 13501-1B-s1,d0AITEX 2021AN0119

What about our panels and curtains?

Here is the class for each product, along with the report supporting it. For curtains, the class of their fabric is given, tested as a curtain performs: that of ILUCS, unglued.

ProductEN 13501-1 classReport
MINERAL FOAM PANEL, self-adhesive, 20 to 60 mmC-s2,d0AITEX 2026AN2267
Mineral foam panel with ILUCS finish, adhesive, 40 mmC-s2,d0 (the foam rating)TECNALIA 080046-001-2-a
Mineral foam panel with IZZER finish, adhesive, 40 mmC-s2,d0 (the foam rating)TECNALIA 080046-001-2-a
MFPXB-s2,d0TECNALIA 080046-002-2
ILUCS CURTAINILUCS: B-s1,d0 (unpasted)BTTG 27/03465E/03/15
IZZER CURTAINIZZER: C-s1,d0BTTG 27/05749B/11/21
PX500 CURTAINPX500: B-s1,d0AITEX 2021AN0119

Is there an equivalence between Euroclass, M1, and B1?

France publishes an equivalence between its M classes and the Euroclasses (decree, arrêté, of November 21, 2002, Annex 4), designed for construction products. Beyond that, each standard has its own test and criteria, as you have seen in the tables, and a table that "converts" one class into another does not replace the test report. If your project requires M1, a test or certificate for M1 is required; if it requires B-s1,d0, one according to EN 13501-1 is required. That is why ILUCS has documentation for each standard.

What a fire classification does not tell you

  • Which class your project requires: it is set by local regulations and premises usage, and specified by the designer.
  • How a different assembly performs compared to the tested one: the rating applies specifically to the tested sample and mounting method.
  • The rating of the finished product versus that of the fabric alone: as shown, they are not the same.

Our pieces for this

Frequently asked questions

What reaction to fire class does the ILUCS CURTAIN have?

In Spain, the CTE (DB-SI, section SI 1) requires curtains in public buildings to meet Class 1 of EN 13773. Approval 250347.1 from Indorama Ventures covers this class for a 300 g/m² gray ILUCS: ask us for the document. Furthermore, ILUCS tested unattached, as a hanging curtain works, is B-s1,d0 according to EN 13501-1 (BTTG 27/03465E/03/15). And ILUCS complies with Part 7 of the IMO FTP Code (AITEX 2024AU1433).

Is M1 the same as B-s1,d0?

No. They are two different systems, with different tests. ILUCS has both: B-s1,d0 due to its European test and M1 due to approval from Indorama Ventures. But having one does not grant the other.

If the fabric is B-s1,d0, is the panel as well?

Not necessarily. In our case, the self-adhesive 40 mm mineral foam panel with ILUCS finish achieves C-s2,d0 (the rating of the foam itself), even though ILUCS alone is rated B-s1,d0.

Is IZZER fire-retardant?

Yes. IZZER is virgin merino wool, without fire-retardant treatment, and its European test, commissioned by ISINAC, gives it C-s1,d0 (BTTG 27/05749B/11/21). Its warranty is 10 years, like that of all ISINAC products.

Where can I download the fire reports?

Tags: sound absorption