Sound absorption coefficient: αw, NRC, and classes A-E

November 13, 2026 · News
Ceiling of a lecture room at the University of Oviedo with square sound-absorbent panels

Quick response: the sound absorption coefficient indicates what portion of the sound reaching a material stays within it and does not return to the room: 0.00 is none and 1.00 is all. αw (standard EN ISO 11654) summarizes it in a single number, from which the absorption class is derived, from A (0.90 to 1.00) to E (0.15 to 0.25). NRC is another summary from the US standard ASTM C423. The Euroclass reaction to fire (EN 13501-1), such as B-s1,d0, measures a different property: a panel can have an absorption class A and a very different Euroclass reaction to fire. Our mineral foam panels are C-s2,d0, and with PX210 they reach B-s2,d0 (MFPX: mineral foam + PX210).

What is the sound absorption coefficient?

When sound reaches a wall, part of it bounces and another part stays in the material. The sound absorption coefficient is that part that stays. In a room, it is what determines how long it takes for sound to fade away: with surfaces that absorb little sound, every word mixes with the echo of the previous one.

It is not calculated: it is measured. The laboratory places the material in a reverberation room (EN ISO 354 standard), measures how long it takes for sound to decay with and without the sample, and derives the absorption from the difference. And it is not a single value: it changes with frequency. A material can absorb almost everything at high frequencies and very little at low frequencies, which is why the test yields a curve, band by band.

αs, αp, and αw: what is the difference?

These are three ways to present the same test result, from the most detailed to the most summarized:

  • αs: measured by the laboratory in one-third octave bands from 100 to 5000 Hz (EN ISO 354). It can exceed 1.00: the standard itself allows this, for example due to diffraction effects. It is not a testing error.
  • αp (practical sound absorption coefficient): groups third octaves into octaves from 125 to 4000 Hz. It is the average of the three one-third octave bands for each octave, rounded in steps of 0.05 and capped at 1.00 (EN ISO 11654, section 4.1).
  • αw (weighted sound absorption coefficient): a single number. The αp curve is compared to a reference curve, which is lowered in steps of 0.05 until the amount the material falls below it totals no more than 0.10. The αw is the value of that curve at 500 Hz (EN ISO 11654, section 4.2).

This is the reference curve of the standard, before shifting it down:

Octave250 Hz500 Hz1000 Hz2000 Hz4000 Hz
Reference curve (EN ISO 11654, figure 1)0.801.001.001.000.90

What do the letters L, M, and H mean in αw?

If in any octave band αp exceeds the shifted reference curve by 0.25 or more, one or more letters in parentheses are added to αw. They warn that the material absorbs significantly more at those frequencies than indicated by the single figure, and the standard recommends reviewing the full curve.

IndicatorWhere the excess isExcess over shifted curve
L (bass)250 Hz0.25 or more
M (mid frequencies)500 Hz or 1000 Hz0.25 or more
H (high frequencies)2000 Hz or 4000 Hz0.25 or more

Thus, «0.85 (H)» means: αw 0.85, and in the high frequencies the material absorbs considerably more than that. An αw without a letter is neither worse nor better: it only indicates that the curve resembles the reference curve.

Absorption classes A, B, C, D and E: how are they assigned?

The absorption class comes directly from αw, using Table B.1 of Annex B of standard EN ISO 11654. No other data is needed:

Absorption classαw values
A0.90 · 0.95 · 1.00
B0.80 · 0.85
C0.60 · 0.65 · 0.70 · 0.75
D0.30 · 0.35 · 0.40 · 0.45 · 0.50 · 0.55
E0.15 · 0.20 · 0.25
Unclassified0.00 · 0.05 · 0.10

Because the class depends on αw, and αw depends on how the product is tested, the class also changes with thickness and mounting. Self-adhesive exposed mineral foam, for instance, is Class D at 20 mm, Class C at 40 mm, and Class A at 60 mm (as seen in the table below).

Example: the real curve of a 40 mm ILUCS panel, band by band

This is the 40 mm adhesive ILUCS panel, tested by TECNALIA (report B2018-LACUS-IN-27 II) surface-mounted without an air gap. First, what the laboratory measured in each third-octave band and how it is converted to octave bands:

Octaveαs measured in its three third-octave bandsMediumαp
125 Hz100 Hz: 0.08 · 125 Hz: 0.15 · 160 Hz: 0.230.150.15
250 Hz200 Hz: 0.35 · 250 Hz: 0.51 · 315 Hz: 0.720.530.55
500 Hz400 Hz: 0.90 · 500 Hz: 1.03 · 630 Hz: 1.061.001.00
1000 Hz800 Hz: 1.14 · 1000 Hz: 1.17 · 1250 Hz: 1.171.161.00
2000 Hz1600 Hz: 1.13 · 2000 Hz: 1.13 · 2500 Hz: 1.081.111.00
4000 Hz3150 Hz: 1.08 · 4000 Hz: 1.07 · 5000 Hz: 1.041.061.00
  • 125 Hz: 0.15. In the lowest bass, this panel absorbs little, and αw does not show it.
  • 250 Hz: the average is 0.53, which in steps of 0.05 rounds to 0.55.
  • 500 Hz: the average is 1.00. From here on, the panel absorbs everything the scale can measure.
  • From 1000 to 4000 Hz: the third-octaves exceed 1.00 (up to 1.17 at 1000 and 1250 Hz), but αp stays at 1.00, which is the maximum limit.

Now, the αw. The reference curve is shifted down and you check how far below it the panel falls:

OctavePanel αpShifted down curve to 0.85Below, with 0.85Above, with 0.85Shifted down curve to 0.90Below, with 0.90
250 Hz0.550.650.100.000.700.15
500 Hz1.000.850.000.150.900.00
1000 Hz1.000.850.000.150.900.00
2000 Hz1.000.850.000.150.900.00
4000 Hz1.000.750.000.250.800.00
  • With the curve lowered to 0.85, the panel only remains below at 250 Hz, and by 0.10: it is within the limit.
  • With the curve at 0.90, at 250 Hz it would be 0.15 below, which is more than 0.10: it is not valid.
  • The αw is the value of the curve at 500 Hz at the last valid position: 0.85.
  • At 4000 Hz, the panel remains 0.25 above the curve: this is why it carries the letter H.
  • Result: αw 0.85 (H), class B. This is the same as stated in the laboratory report.

What is NRC and how does it differ from αw?

The NRC (noise reduction coefficient) is the summary used in the United States. It comes from the ASTM C423 standard, which also measures in a reverberation room, and is the average of the absorption coefficient at 250, 500, 1000 and 2000 Hz, rounded to 0.05. It is similar to αw in that it is a single number, but it is not the same:

  • It does not account for 125 Hz or 4000 Hz.
  • It is a simple average without a reference curve: an opening in one band is covered by excess absorption in another. αw, on the other hand, penalizes openings.
  • It does not include L, M, or H indicators, and does not provide an absorption class.

Our laboratory reports and declarations of performance provide the αw according to EN ISO 11654, complete with its full curve. To compare with a product that only publishes NRC, the safest option is to request its octave band curve: with both curves side by side, two materials can be compared fairly.

In Spain, furthermore, the Technical Building Code (CTE DB-HR, section 3.2) requires the mean sound absorption coefficient αm of the 500, 1000, and 2000 Hz bands for calculating reverberation time, and only allows using αw if it is not available. Another reason not to rely on just one number.

Does sound absorption class A have anything to do with fire class?

Nothing. The absorption class indicates how much sound remains in the material. The reaction to fire Euroclass (standard EN 13501-1; in Spain, Royal Decree 842/2013) describes how the material behaves when exposed to fire, using a different test. It is written in three parts:

PartWhat it measuresValues
LetterReaction to fire of the productA1, A2, B, C, D, E, F
sSmoke productions1, s2, s3 (s1 produces the least smoke; s3 is «neither s1 nor s2»)
dFlaming droplets and particlesd0: none during the 600 s of the SBI test (UNE-EN 13823) · d1: none for more than 10 s · d2: neither d0 nor d1

Thus, B-s1,d0 means class B, low smoke emission, and no flaming droplets. Class A sound absorption has nothing to do with class A1 or A2 reaction to fire, and the exact same product can have two very different ratings. Our 40 mm self-adhesive IZZER panel has Class A sound absorption (αw 0.90), while its Euroclass reaction to fire as a complete product is C-s2,d0, determined by the mineral foam core. Conversely, the 1-layer ILUCS CURTAIN has the B-s1,d0 Euroclass reaction to fire of ILUCS and Class D sound absorption (αw 0.45 (H)). When a project demands higher reaction to fire standards, there is MFPX, mineral foam + PX210: B-s2,d0 in its test (TECNALIA 080046-002-2).

Sound absorption coefficient of our products: αw, class, and Euroclass

All data are from laboratory tests. Each αw applies to the mounting arrangement tested, shown in parentheses:

Product (test assembly)αwAbsorption classEuroclassAbsorption report
Adhesive IZZER panel, 40 mm (glued)0.90AC-s2,d0TECNALIA B2021-LACUS-IN-146-3
Self-adhesive ILUCS panel, 40 mm (glued)0.85 (H)BC-s2,d0TECNALIA B2018-LACUS-IN-27 II
Suspended ILUCS panel, 40 mm (400 mm from the surface)0.80 (H)BC-s2,d0TECNALIA B2019-LACUS-IN-54 II
Exposed mineral foam, self-adhesive, 20 mm (bonded)0.40 (MH)DC-s2,d0TECNALIA 110259-2
Exposed mineral foam, self-adhesive, 40 mm (glued)0.75 (MH)CC-s2,d0TECNALIA B2018-LACUS-IN-27 III
Exposed mineral foam, self-adhesive, 60 mm (glued)1.00AC-s2,d0TECNALIA 110259-1
ILUCS CURTAIN, 1 layer (300 mm from the wall)0.45 (H)DB-s1,d0 (ILUCS)TECNALIA 115541-3
ILUCS CURTAIN, 4 layers (200 mm from the wall)1.00AB-s1,d0 (ILUCS)TECNALIA B2019-LACUS-IN-54 V
PX500 CURTAIN, 1 layer (300 mm from the wall)0.80 (H)BB-s1,d0 (PX500)TECNALIA 115541-1

The absorption class is derived from αw using the table in the standard: several reports only provide αw, and the letter is read in Table B.1. Fire classes come from their own reaction to fire reports, which are located, like absorption reports, under Certificates.

What the absorption coefficient doesn't tell you

Frequently asked questions

What is a good sound-absorption coefficient?

It depends on what the room requires, but as a benchmark: from 0.80 it is Class B, and from 0.90 it is Class A. More important than the letter class is how many square meters you install, where you place them, and whether the product also absorbs sound at low frequencies when the room needs it.

Can NRC be converted to αw, or vice versa?

There is no exact equivalence: they are calculated using different frequency bands and rules, and each derives from its own test standard. If you have both octave band curves, compare the curves.

Why does one report say «0.85 (H)» and another «0.85»?

Both absorb the same according to αw. The letter H warns that the first one absorbs significantly more in the high frequencies (2000 or 4000 Hz) than the number indicates.

Is a sound absorption coefficient greater than 1.00 an error?

No. The αs measured by the laboratory per third-octave band can exceed 1.00, and the testing standard permits this. In the example in this article, it reaches 1.17. When converted to octave bands, αp is capped at 1.00.

How do I know how much my room absorbs?

Tags: sound absorption